Cut the particles of RO raw water and provide highly purified raw water to RO membrane.
@Life extension of RO Module
By effectively removing the particles within raw water that causes module clogging, we can extend the life of RO membrane.
@Reduction of endotoxin concentration within raw water
Because approx. 90% of endotoxin concentration within raw water can be prevented, it can suppress the contamination of RO membrane.
Model | LL-01 | LL-02 | LL-03 |
Standard treatment water volume(at 25j | 1400L/h | 2800L/h | 4200L/h |
Maximum treatment water volume(at 25j | 1600L/h | 3200L/h | 4800L/h |
Number of membranes | P | Q | R |
Corresponding RO model | `MH255 | `MH752 | `MH754 |
RO recovery ratio | `75 | ||
Automatic flushing mechanism | Standard equipment | ||
Power | 1Σ 100V x 1kW | ||
External dimension | 400 x 900 x 1800 | 500 x 900 x 1800 | 600 x 900 x 1800 |
Operating weight (kg) | 350 | 430 | 520 |
1.@Depending on the raw water quality, RO's high recovery ratio operation may not be done.
2.@If you are installing it to an existing RO, please contact our company.
3.@We have a membrane washing tank unit as an option.
4.@Please note that specifications and appearance may change without notice.