New Circulation Operation Method: Fusion of Water Quality and Ecology
Based on "multi-recirculation system", by combining "all automatic chemical solution cleansing and sterilization system" and "RO recovery ratio automatic adjusting mechanism", we have achieved the coexistence of both improved water quality and being eco-friendly.
Furthermore, through built-in integration of "clean eco system (RO drain water recovery equipment), it has become possible to significantly improve the water saving effects.
uCleanv
E@RO membrane recirculation operation from the loop line (multi-recirculation system)
E@Equipped with high performance RO membrane
E@Advanced completely automatic chemical solution cleansing and sterilization system (maintains sterilization of RO membrane)
E@Adopted new sampling port which meets cleanliness
E@Improved raw water quality with the clean eco system
E@Adopted PVDF piping
E@Bypass line automatic flushing system
uEcov
E@Drain water control with RO recovery ratio automatic adjusting function
E@Saves water with the re-use of RO drain water
E@Saves power by making pump an inverter
E@Re-use of initial drain water
uCompactv
E@Inherited the MX'E's compact design
E@Downsized by having a model without the softener
E@Built-in integration of clean eco system
uUsabilityv@
E@Adopted RO membrane removal rate monitor
E@Highly functional large color LCD touch panel
E@One-touch automatic bypass (With RO water desalination mechanism of raw water pump)
E@Initial drained water quality monitoring mechanism
Model | TYPE-1 | TYPE-2 | TYPE-3 | ||||||
251 | 252 | 253 | 254 | 751 | 752 | 753 | 754 | ||
Standard permeation water volume (L/h) |
At 25 | 200 | 400 | 600 | 800 | 1,100 | 2,100 | 3,100 | 3,800 |
Drain water recovery system (clean eco) | (Optional) | (Optional) | (Optional) | (Optional) | Standard built-in | Standard built-in | Standard built-in | Standard built-in | |
RO module (main) | 4 inch room temperature membrane specification | 1 | 2 | 3 | 4 | - | - | - | - |
8 inch room temperature membrane specification | - | - | - | - | 1 | 2 | 3 | 4 | |
Drain water recovery module | 4 inch LF membrane | (Optional) | (optional) | (optional) | (optional) | - | - | - | - |
8 inch LF membrane | - | - | - | - | 1 | 1 | 2 | 2 | |
Raw water heater(kW) | 7-25 | 10 | 15 | 25 | 30 | 40 | 70 | 110 | 120 |
Pre-filter(o) | 10Κ | 750~1 | 750~1 | 750~3 | |||||
Water softener resin volumeiLj | 42 | 60 | 90 | ||||||
Active coal filter(o) | 750~3 | 750~5 | 750~8 | ||||||
Raw water tank(L) | 100 | 100 | 139 | ||||||
Raw water pressurization pump(kW) | Inverter specification | 0.74 | 1.7 | 1.7 | 2.5 | ||||
RO pump(kW) | Inverter specification | 4.0 | 4.0 | 5.5 | |||||
RO recovery pump(kW) | Inverter specification | - | 4.0 | 4.0 | |||||
Water supply pump(kW) | Inverter specification | 0.74~2 | 0.74~2 | 0.74~2 | |||||
RO water tankiL) | 137 | 137 | 205 | ||||||
UV bactericidal lamp(W) | Immersion type | 60 | 60 | 60 | |||||
DimensioniW x D x H) | 1,320~1,000~1,800 | 1,670~1,000~1,800 | 2,620~1,000~1,800 | ||||||
Number of cabinets | 2 | 3 | 5 | ||||||
Operating weightikg) | 1,330 | 1,350 | 1,370 | 1,380 | 1,680 | 1,740 | | | |
Power(kW) 50/60Hz |
3Σ@200V | 6.22 | 11.18 | 12.68 | 13.48 | ||||
Breaker volume (In case with B, E, pressurization P) | 50AF/50A | 100AF/75A | 100AF/75A i100AF/100Aj |
100AF/100A | |||||
1Σ100V | 1.0 | 1.0 | 1.0 | ||||||
Breaker volume | 30AF/10A | 30AF/10A | 30AF/10A | ||||||
Connecting pipesiAj | Raw water inlet | 25~1 | 25~1 | 32~1 | |||||
Clear water outlet | 20~2 | 20~2 | 25~2 | ||||||
Drain water outlet | 32~1 | 32~2 | 32~2 | ||||||
Raw Water Heating Method | Electric heater method (standard specification), hot water direct introduction method, boiler circulation method, heat exchange method |